LIVING/ DINING/ LOBBY/ PASSAGE | |
Floors | Imported Marble |
Walls | Acrylic Emulsion paint on POP punning |
Ceiling | Acrylic Emulsion paint with limited False Ceiling. |
BEDROOMS | |
Floor | Laminated wooden flooring |
Walls | Acrylic Emulsion paint on POP punning |
Ceiling | Acrylic Emulsion paint with limited False Ceiling. |
KITCHEN | |
Walls | Tiles up-to 2' above counter & Acrylic Emulsion paint in balance area. |
Floor | Anti-skid Tiles. |
Ceiling | Acrylic Emulsion paint. |
Counter | With Marble/Granite/Artificial Marble top. |
Fittings/ Fixtures | CP fittings of Kohler/Jaguar or equivalent, Single bowl SS Sink with additional SS Sink with drain bowl SS Sink with additional SS Sink with drain board in utility balcony. |
Wood Work | Modular Kitchen without chimney & hob. |
BALCONY & UTILITY BALCONY | |
Floor | Ceramic Tiles. |
Ceiling | Exterior paint. |
TOILETS | |
Walls | Combination of Tiles, Acrylic Emulsion Paint & Mirror. |
Floors | Anti-Skid Tiles/Marbel. |
Ceiling | Acrylic Emulsion Paint. |
Counters | With Marble/Granite/Synthetic stone top. |
Fixture/Accessories | Glass Shower-partition in toilets (7'Ht), & Glass enclosure (7ft') for W.C. in Master Toilet. |
Sanitary ware/CP fittings | Single Lever CP fittings of Kohler/Jagaur or equivalent make. Wash Basin, Floor mounted/ Wallhung WC of Parryware/Hindware or Equivalent make. |
PLUMBING | |
CPVC & UPVC piping for water supply inside the toilet & kitchen and vertical down takes. | |
FIRE FIGHTING SYSTEM | |
Fire Fighting System with sprinklers, smoke detection system etc. as per NBC norms. | |
SERVANT & STORE ROOM | |
Floor | Grey Mosaic cast-in-situ flooring/Tiles/Terrazzo. |
Walls & Ceiling | Oil bound Distemper. |
Toilets | Ceramic Tile Flooring & Cladding, conventional CP Fittings. |
DOORS | |
Internal Doors | 8’ high Polished Hard wood frame with Polished Moulded Skin shutters. |
Entrance door | 8’- high Polished Hard wood frame with Polished Designer door |
EXTERNAL GLAZINGS | |
Windows/ External Glazing | UPVC / Powder Coated Aluminum Glazing with reflective glass or clear glass & Aluminum/ UPVC Glazing with clear Frosted Glass in Kitchen, Toilets & Servant room. |
ELECTRICAL FIXTURES/ FITTINGS | |
Modular switches of Crabtree/ MK/ Schneider or equivalent make with copper wiring, and ceiling light fixtures in Balconies. | |
POWER BACK-UP | |
100% DG Power back-up as mentioned below: | |
a) 2350 sq.ft. | Not exceeding 10 KVA oer apartment. |
b) 2850/2890 sq.ft. | Not exceeding 10 KVA oer apartnert. |
c) 3200/3260 sq.ft. | Not exceedirg 10 KVA oer apartrrert. |
d) 4150 sq.ft. | Not exceeding 15 KVA per apartrrert. |
e) 4570 sq.ft. | Not exceeding 15 KVA per apartment. |
DG Capacity shall be at 70% of load factor 8 70% over-all diversity for apartments as well as for common areas | |
SECURITY SYSTEM | |
Secured Gated Community. CCTV in driveway of Parking Basements, Ground Floor & Basement Entrance Lobbies. Video Door-Phone and one intercom point in each apartment. |
|
LIFT LOBBY | |
Lifts | Passenger and Service Elevators of Mitsubishi/OTIS or equivalent |
Lift Lobby Floor | Combination of Granite/Marble/Tiles |
Lift Lobby Walls | Combination of Granite/Acrylic Emulsion Paint on POP Punning/Textured Paint |
STAIRCASES | |
Floor | Terrazzo/ Mosaic Tiles/Marble/Kota Stone |
Walls | Flat oil Paint |
CLUB FACILITY | |
Multi Purpose Hall with Banqueting Facility, Restaurant/ Coffee shop, Convenience Shop, Business Center, Children Play Area, Gymnasium with Modern Equipments, Unisex Saloon, Steam & Jacuzzi, Outdoor Swimming Pool with separate Kids Pool, Temperature Maintained Indoor Pool, Cards & Carrom Room, Billiard's Room, Table Tennis Room, Indoor Badminton Court (2 nos), Squash Court (2 nos), Lawn Tennis Court. | |
CONVERSION SCALE | |
1ft. | 304.8 mm |
Disclaimer:- Colour & Design of tiles can be changed without prior notice. All products such as marble / granite/ wood/ tiles have inherent characteristics of slight variation in texture colour, grain variations, cracks and behavior. Specifications are indicative and are subject to change as decided by the Company/ Architect or Competent Authority. Marginal variations may be necessary during construction. The extent/ number/ variety of the equipments/ appliances and their make/ brand thereof are tentative and liable to change at sole discretion of the company. Applicant / Allottee shall not have any right to raise objection in this regard. |